Application of contrast-enhanced  ultrasonography after radiofrequency ablation  for renal cell carcinoma: is it sufficient  for assessment of therapeutic response?

Application of contrast-enhanced ultrasonography after radiofrequency ablation for renal cell carcinoma: is it sufficient for assessment of therapeutic response?

  • نوع فایل : کتاب
  • زبان : انگلیسی
  • مؤلف : Wen-Tao Kong, Wei-Wei Zhang, Hong-Qian Guo, Jun-Lan Qiu, Min Tang, Zhi-Min Jiang,Yi Shen, Xiao-Gong Li, Shi-Wei Zhang
  • چاپ و سال / کشور: 2010

Description

Purpose: To assess the efficacy of contrast-enhanced ultrasonography (CEUS) with Sonovue in the evaluation of therapeutic response to radiofrequency ablation (RFA) of renal cell carcinoma (RCC). Materials and methods: In a recent 3 years, 63 patients (mean age, 60 years; range 26–81 years) with 64 RCCs were treated by RFA. The lesions had a diameter between 1.8 and 9.8 cm (average diameter, 3.1 cm). The indications for RFA treatment included chronic renal insufficiency (n = 10), presence of solitary kidney (n =3), bilateral renal carcinoma (BRCC) (n =2), advanced age (n =12), significant medical comorbidity (n =29) or refusal of conventional therapy (n =7). Tumors were treated by laparoscopy-assisted (n =41), open surgical (n =18) or percutaneous US guidance (n =4). Follow-up CEUS and contrast-enhanced CT were performed 1 month after treatment to assess the necrotic area. Technical success was defined as elimination of areas that enhanced at imaging within the entire tumor. Results: On the 1-month CEUS and CT imaging after RFA, 62 of 64 tumors (96.9%) were successfully ablated with one session, and residual tumors were found in two RCCs. One of the two tumors was subjected to additional RFA treatment. We could not obtain a complete ablation in the other tumor of a patient with solitary kidney. The diagnostic concordance between the CEUS and 1-month follow-up CT was 100%. Sixtyone patients survived in the follow-up phase which ranged from 2 to 34 months. One patient with solitary kidney died of systemic disease progression and one patient was lost to follow-up. Of the 61 tumors without residual on both CT and CEUS after RFA, four had suspicious findings of recurrence on follow-up CEUS, and two of them were confirmed by subsequent CT examination. With CT as the reference imaging procedure in the assessment of renal tumor ablation, the sensitivity, specificity, positive predictive value, and negative predictive value of CEUS for detecting recurrence during follow-up were 100%, 96.6%, 50%, and 100%. Conclusion: Despite its limitation of false-positive value, CEUS is potentially effective in assessing the therapeutic response to RFA of RCC.
Abdom Imaging (2011) 36:342–347 ª Springer Science+Business Media, LLC 2010 Published online: 25 November 2010
اگر شما نسبت به این اثر یا عنوان محق هستید، لطفا از طریق "بخش تماس با ما" با ما تماس بگیرید و برای اطلاعات بیشتر، صفحه قوانین و مقررات را مطالعه نمایید.

دیدگاه کاربران


لطفا در این قسمت فقط نظر شخصی در مورد این عنوان را وارد نمایید و در صورتیکه مشکلی با دانلود یا استفاده از این فایل دارید در صفحه کاربری تیکت ثبت کنید.

بارگزاری