Bilateral subthalamic deep brain stimulation using single track microelectrode recording

Bilateral subthalamic deep brain stimulation using single track microelectrode recording

  • نوع فایل : کتاب
  • زبان : انگلیسی
  • مؤلف : Won Seok Chang , Hae Yu Kim , Joo Pyung Kim , Young Seok Park , Sang Sup Chung , Jin Woo Chang
  • چاپ و سال / کشور: 2011

Description

Background Microelectrode recording (MER) is widely used during deep brain stimulation (DBS) procedures because MER can identify structural borders and eloquent structures, localize somatotopic arrangements, and provide an outline of the three-dimensional shapes of target nuclei. However, MER may cause intracranial hemorrhage. We preformed single track MER during DBS procedures, analyzed the accuracy of electrode positioning with MRI, and compared the amount of air and the potential risk of intracranial hemorrhage. Method A total of 46 electrodes were placed in 23 patients who suffered from advanced Parkinson’s disease and who underwent bilateral subthalamic nucleus DBS using single track MER. Each patient’s Unified Parkinson’s Disease Rating Scale (UPDRS) score and levo-dopa equivalent dosage (LED) were estimated pre- and postoperatively. The accuracy of electrode positioning and fontal air thickness was measured by a pre- or postoperative magnetic resonance imaging (MRI) merging technique. Findings The mean electrode positioning error was 0.92 mm (0.3–2.94 mm). The mean frontal air thickness on postoperative MRI was 3.85 mm (0–10.3 mm), which did not affect the electrode accuracy statistically (p=0.730). A total of nine electrodes required repositioning after single-track MER because they affected microstimulation or because an abnormally short STN length was observed during MER. In this series, one patient suffered from an intracranial hemorrhage after surgery that appeared to be due to venous infarction rather than related to MER. Conclusions Although MER can facilitate accurate positioning of electrodes, multi-track MER may increase the risk of intracranial hemorrhage. The accuracy of electrode positioning appears to be acceptable under single track MER during STN DBS with careful electrophysiological and neurological monitoring. The risk of intracranial hemorrhage appears to be minimal, especially in elderly patients with atrophic brains.
Acta Neurochir (2011) 153:1087–1095 DOI 10.1007/s00701-011-0953-1 Received: 3 September 2010 / Accepted: 19 January 2011 / Published online: 11 February 2011 # Springer-Verlag 2011
اگر شما نسبت به این اثر یا عنوان محق هستید، لطفا از طریق "بخش تماس با ما" با ما تماس بگیرید و برای اطلاعات بیشتر، صفحه قوانین و مقررات را مطالعه نمایید.

دیدگاه کاربران


لطفا در این قسمت فقط نظر شخصی در مورد این عنوان را وارد نمایید و در صورتیکه مشکلی با دانلود یا استفاده از این فایل دارید در صفحه کاربری تیکت ثبت کنید.

بارگزاری