Rates of pathological underestimation for 9 and 12 gauge breast needle core biopsies at surgical excision

Rates of pathological underestimation for 9 and 12 gauge breast needle core biopsies at surgical excision

  • نوع فایل : کتاب
  • زبان : انگلیسی
  • مؤلف : Stamatia Destounis Melissa N. Skolny Renee Morgan Andrea Arieno Philip F. Murphy Patricia Somerville Posy Seifert Wende Young
  • چاپ و سال / کشور: 2011

Description

Background The clinical implementation of needle core biopsies has given radiologists an invaluable tool for the diagnostic evaluation of suspicious breast lesions. Despite improvements made to the technology of breast biopsy, the underestimation of disease in tissue samples retrieved continues. This can be attributed to many factors, including variability between different needle gauges. This study was undertaken to assess the pathological underestimation for 9 and 12 gauge breast needle core biopsies at surgical excision. Materials and methods A retrospective review of imageguided consecutive core needle biopsies performed from 2003 to 2006 yielded a total of 1,201 needle core biopsies: 837 twelve gauge and 364 nine gauge. Further analysis was completed to distinguish needle biopsies whose pathological outcome was underestimated at core needle biopsy when compared to their subsequent surgical excision. Ninety-seven lesions in 88 patients were reviewed and comprise the study cohort. Results Underestimation was found in 97 needle core procedures in 88 patients. Of the 97, 67 were performed with 12 gauge vacuum-assisted biopsy devices and 30 with 9 gauge vacuum-assisted biopsy devices, resulting in an underestimation rate of 8.00 and 8.24% for 12 gauge and 9 gauge, respectively. The difference in underestimation rate was not statistically significant per Pearson’s chi squared test (P = 0.8898). Conclusion In this analysis, the underestimation of needle biopsy results with surgical pathology was found to be 8.00% for the 12 gauge group and 8.24% for the 9 gauge group. These results support our current clinical practice of utilizing either needle gaug
Breast Cancer (2011) 18:42–50 DOI 10.1007/s12282-010-0201-1 Received: 25 November 2009 / Accepted: 27 January 2010 / Published online: 4 March 2010  The Japanese Breast Cancer Society 2010
اگر شما نسبت به این اثر یا عنوان محق هستید، لطفا از طریق "بخش تماس با ما" با ما تماس بگیرید و برای اطلاعات بیشتر، صفحه قوانین و مقررات را مطالعه نمایید.

دیدگاه کاربران


لطفا در این قسمت فقط نظر شخصی در مورد این عنوان را وارد نمایید و در صورتیکه مشکلی با دانلود یا استفاده از این فایل دارید در صفحه کاربری تیکت ثبت کنید.

بارگزاری