Description

Endovascular treatment for a wide-neck anterior communicating artery (AcomA) aneurysm remains technically challenging. Stent-assisted embolization has been proposed as an alternative of treatment of complex aneurysms. The X-configuration double-stent-assisted technique was used to achieve successful coiling of wideneck AcomA aneurysm. Implanted stent can alter intraarterial flow. Follow-up angiograms 4 months later showed flow changes due to used X-technique of stents implantation and filling of the anterior cerebral artery from the opposite internal carotid artery.
Cardiovasc Intervent Radiol DOI 10.1007/s00270-011-0153-7 Received: 21 December 2010 / Accepted: 14 March 2011