Immediate versus conventional loading of palatal implants in humans: a first report of a multicenter RCT

Immediate versus conventional loading of palatal implants in humans: a first report of a multicenter RCT

  • نوع فایل : کتاب
  • زبان : انگلیسی
  • مؤلف : Britta A. Jung ,Winfried Harzer ,Heinrich Wehrbein ,Tomasz Gedrange ,Werner Hopfenmüller ,Gabriele Lüdicke ,Maximilian Moergel ,Peter Diedrich ,Martin
  • چاپ و سال / کشور: 2010

Description

This study aims to analyze the clinical performance of two loading concepts on second-generation palatal implants (Orthosystem, Straumann, Basel, Switzerland) in a prospective multicenter randomized controlled clinical trial. At the time of this interim analysis, 41 patients have been randomized on a 1:1 basis to one of two treatmentgroups. Group 1 underwent conventional loading of palatal implants after a healing period of 12 weeks (gold standard) while group 2 underwent immediate implant loading within 1 week after implant insertion. We report initial results at 6 months after functional loading. The primary outcome parameter was implant success (no implant mobility, no implant loss). The implants in both groups were initially stable at the time of insertion, and all were eligible for randomization. Twenty-two patients (group 1) were subjected to conventional implant loading after 12 weeks while 19 patients (group 2) received immediate functional loading within the first week after insertion. Direct (e.g. distal jet appliances) as well as indirect forms of anchorage (conventional or modified transpalatal arch) were used. The magnitude of orthodontic forces ranged between 1 and 4 N for the immediate loading group and between 1 and 5 N for the conventional loading group. One implant in group 1 was lost during the healing phase. One dropout was registered in group 2. Thirty-nine implants were functionally loaded for over 6 months now. These preliminary data provide first evidence of the fact that immediate loading of palatal implants yields equivalent success rates as conventional loading to 4 N after 6 months.
Clin Oral Invest (2011) 15:495–502 DOI 10.1007/s00784-010-0407-9 Received: 23 September 2009 / Accepted: 18 March 2010 / Published online: 10 April 2010
اگر شما نسبت به این اثر یا عنوان محق هستید، لطفا از طریق "بخش تماس با ما" با ما تماس بگیرید و برای اطلاعات بیشتر، صفحه قوانین و مقررات را مطالعه نمایید.

دیدگاه کاربران


لطفا در این قسمت فقط نظر شخصی در مورد این عنوان را وارد نمایید و در صورتیکه مشکلی با دانلود یا استفاده از این فایل دارید در صفحه کاربری تیکت ثبت کنید.

بارگزاری