Emergency medicine residents’ ability to identify ocular pathology in a live porcine model

Emergency medicine residents’ ability to identify ocular pathology in a live porcine model

  • نوع فایل : کتاب
  • زبان : انگلیسی
  • مؤلف : Vincent L. Ball Bradley N. Younggren Jason D. Bothwell
  • چاپ و سال / کشور: 2011

Description

Objective To evaluate emergency medicine residents’ ability to detect ocular pathology using portable ultrasound (US) in a live porcine model. Methods This was a pilot study to evaluate emergency medicine residents’ ability to accurately diagnose ocular pathology in a porcine model using handheld US. Subjects were emergency medicine residents who had all undergone a 2-day US course as part of their emergency medicine orientation month and had reviewed an 1 h self-instruction computer tutorial on ocular US prior to the study. Vitreous hemorrhages, retro-orbital hematomas and intraocular foreign bodies were simulated by placement of porcine blood and metallic objects under ultrasound guidance out of view of the subject population. Residents then performed selfdirected US of two eyes each and were asked to comment on any pathology observed. Some residents were also asked to identify central retinal artery flow. Time required for each scan was noted. Results A total of 36 residents scanned 6 porcine eyes over 2 lab iterations. EM residents were able to detect a significant abnormality greater than 93% of the time. Vitreous hemorrhages were the most detectable injuries with 95% accuracy. A significant abnormality was detected in the models with intraocular foreign bodies 97% of the time with a clear diagnosis of foreign body noted in 73% of the cases. Retro-orbital hematoma was the most difficult to detect with 62% accuracy. The average time taken for scanning two eyes was 7 min 38 s. Central retinal artery flow was detected in 100% of the 26 cases in which this was documented. Accuracy of diagnoses was similar across levels of EM training. Conclusion EM residents can accurately diagnose significant ocular pathology using handheld US in a live porcine model
Crit Ultrasound J (2011) 3:13–17 DOI 10.1007/s13089-011-0053-8 Received: 15 April 2010 / Accepted: 26 January 2011 / Published online: 17 February 2011
اگر شما نسبت به این اثر یا عنوان محق هستید، لطفا از طریق "بخش تماس با ما" با ما تماس بگیرید و برای اطلاعات بیشتر، صفحه قوانین و مقررات را مطالعه نمایید.

دیدگاه کاربران


لطفا در این قسمت فقط نظر شخصی در مورد این عنوان را وارد نمایید و در صورتیکه مشکلی با دانلود یا استفاده از این فایل دارید در صفحه کاربری تیکت ثبت کنید.

بارگزاری