Defining the Threshold: New Data on the Ability of Capsule  Endoscopy to Discriminate the Size of Esophageal Varices

Defining the Threshold: New Data on the Ability of Capsule Endoscopy to Discriminate the Size of Esophageal Varices

  • نوع فایل : کتاب
  • زبان : انگلیسی
  • مؤلف : Ian Schreibman Kevin Meitz Allen R. Kunselman Matthew Downey Tri Le Thomas Riley
  • چاپ و سال / کشور: 2010

Description

Background Endoscopy (esophagogastroduodenoscopy, EGD) to screen for esophageal varices (EV) is recommended in patients with portal hypertension. Reports indicate that capsule endoscopy (CE) is capable of identifying large/medium varices (L/MV) when the varix comprises more than 25% of the circumference of the field of view. Aims We evaluated the ability of CE to discriminate the size of EV using this grading scale. Methods Patients underwent CE and EGD on the same day. A blinded investigator interpreted capsule findings. CE labeled EV as L/MV if C25% of the lumen circumference was occupied, and small/none for\25%. Results A total of 37 patients were enrolled in this prospective, observational study at a single tertiary-care academic center. Three CE were excluded due to rapid esophageal transit time or technical malfunction. Using a 25% threshold, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for EC to discriminate L/MV were 23.5%, 88.2%, 66.7%, and 53.6%, respectively (j = 0.12). Reducing the threshold to 12.5% resulted in sensitivity, specificity, PPV, and NPV of 88.2%, 64.7%, 71.4%, and 84.6%, respectively (j = 0.53). A receiver-operator characteristic (ROC) curve showed a 15% threshold to be optimal in discriminating EV size using CE, resulting in sensitivity, specificity, PPV, and NPV of 76.5%, 82.4%, 81.3%, and 77.8%, respectively (j = 0.59). Conclusions This study indicates that discriminating EV size by the current capsule scale is unreliable. Lowering the grading threshold improved the ability to discriminate EV size by CE. In the proper context, CE is an alternative to EGD to screen for EV.
Dig Dis Sci (2011) 56:220–226 DOI 10.1007/s10620-010-1272-8 Received: 10 January 2010 / Accepted: 27 April 2010 / Published online: 19 May 2010
اگر شما نسبت به این اثر یا عنوان محق هستید، لطفا از طریق "بخش تماس با ما" با ما تماس بگیرید و برای اطلاعات بیشتر، صفحه قوانین و مقررات را مطالعه نمایید.

دیدگاه کاربران


لطفا در این قسمت فقط نظر شخصی در مورد این عنوان را وارد نمایید و در صورتیکه مشکلی با دانلود یا استفاده از این فایل دارید در صفحه کاربری تیکت ثبت کنید.

بارگزاری