Whole-body CT in polytrauma patients: effect of arm positioning on thoracic and abdominal image quality

Whole-body CT in polytrauma patients: effect of arm positioning on thoracic and abdominal image quality

  • نوع فایل : کتاب
  • زبان : انگلیسی
  • مؤلف : Christoph Karlo & Ralph Gnannt & Thomas Frauenfelder & Sebastian Leschka & Martin Brüesch & Guido A. Wanner & Hatem Alkadhi
  • چاپ و سال / کشور: 2011

Description

The purpose of this study is to assess the influence of different arm positioning techniques on thoracic and abdominal image quality and radiation dose of wholebody trauma CT (wbCT). One hundred and fifty polytrauma patients (104 male, mean age 47±19) underwent wbCT with arms elevated above the head (group A, n=50), alongside the abdomen (group B, n=50), and on a pillow ventrally to the chest with both arms flexed (group C, n=50). Two blinded, independent observers measured image noise and rated image quality (scores 1–3) of the liver, aorta, spleen, spine, and lower lungs. Radiation dose parameters were noted, and the abdomens’ anterior–posterior diameter and scan lengths were measured. Interreader agreements for image noise (r= 0.86; p<0.001) and subjective image quality (k=0.71–0.84) were good. Noise was lower (p<0.05), image quality of the liver, aorta, spleen, and spine was higher, and radiation dose lower in group A than in groups B and C (p<0.001, each). Image quality of the spleen, liver, and aorta were higher in group C than in group B (p<0.05, each). No significant differences in scan length (p=0.61) were found among groups. Abdominal anterior–posterior diameter correlated significantly with noise (r=0.82; p<0.01) and dose (r=0.47; p<0.001). Estimated effective radiation doses were significantly (p<0.001) higher in groups B (21.2 mSv) and C (21.9 mSv) as compared to A (16.1 mSv). In wbCT for polytrauma patients, positioning of the arms above the head results in better image quality and lower radiation dose. Placing the flexed arms on a large pillow ventrally to the chest significantly improves image quality as compared to positioning alongside the abdomen.
Emerg Radiol (2011) 18:285–293 DOI 10.1007/s10140-011-0948-5 Received: 26 January 2011 / Accepted: 4 March 2011 / Published online: 7 April 2011
اگر شما نسبت به این اثر یا عنوان محق هستید، لطفا از طریق "بخش تماس با ما" با ما تماس بگیرید و برای اطلاعات بیشتر، صفحه قوانین و مقررات را مطالعه نمایید.

دیدگاه کاربران


لطفا در این قسمت فقط نظر شخصی در مورد این عنوان را وارد نمایید و در صورتیکه مشکلی با دانلود یا استفاده از این فایل دارید در صفحه کاربری تیکت ثبت کنید.

بارگزاری