Minimally invasive plate osteosynthesis of tibial fracture using self-navigated plate

Minimally invasive plate osteosynthesis of tibial fracture using self-navigated plate

  • نوع فایل : کتاب
  • زبان : انگلیسی
  • مؤلف : Wei Chen · Qi Zhang · Yanling Su · Bo Wang ·Bing Yin · Yingze Zhang
  • چاپ و سال / کشور: 2011

Description

This study aims to introduce a self-navigated plate, which is characterized by the presence of a groove at each end of the plate, in treating tibial fractures. The plate is inserted subperiosteally across the fracture line when the fracture is eVectively reduced. A second plate of the same is then placed over the subcutaneous one and serves as a guide for percutaneous insertion of screws through the holes of subperiosteal plate into the bones to secure the fracture. Seven patients with tibial shaft fractures were treated by minimally invasive plate osteosynthesis (MIPO) using this plate. The average operative time was 47 min, and the average Xuoroscopy time was 19 s. All fractures healed from 3 to 6 months postoperatively, and excellent functional recovery was observed in all patients. In conclusion, the economical-friendly self-navigated plate is a good and eVective alternative Wxation method in treating tibia fractures by MIPO.
Eur J Orthop Surg Traumatol DOI 10.1007/s00590-011-0783-0 Received: 20 November 2010 / Accepted: 11 February 2011
اگر شما نسبت به این اثر یا عنوان محق هستید، لطفا از طریق "بخش تماس با ما" با ما تماس بگیرید و برای اطلاعات بیشتر، صفحه قوانین و مقررات را مطالعه نمایید.

دیدگاه کاربران


لطفا در این قسمت فقط نظر شخصی در مورد این عنوان را وارد نمایید و در صورتیکه مشکلی با دانلود یا استفاده از این فایل دارید در صفحه کاربری تیکت ثبت کنید.

بارگزاری