Flexor tendon repair using a new suture technique: a comparative in vitro biomechanical study
- نوع فایل : کتاب
- زبان : انگلیسی
- مؤلف : M. Scha¨del-Ho¨pfner J. Windolf T. T. Lo¨gters M. Hakimi I. Celik
- چاپ و سال / کشور: 2010
Description
Introduction The purpose of this experimental study was to evaluate the biomechanical characteristics of two new four-strand core suture techniques for flexor tendon repair. Materials and methods The two new suture techniques (Marburg 1, Marburg 2) are characterized by four longitudinal stitches which are anchored by a circular or semicircular suture. They were compared with three commonly used core suture techniques (modified Kessler, Tsuge, Bunnell). Fifty porcine flexor tendons were randomly assigned to one of the five core suture techniques. Outcome measures included ultimate tensile strength, maximum of lengthening, mode of failure and 1 mm gap formation force. Results The highest ultimate tensile strength was found for the modified Kessler technique (115 N). Both new techniques showed an ultimate load exceeding 50 N (57 N for Marburg 1, 54 N for Marburg 2). The Marburg 1 technique showed the highest gap resistance of all tested suture techniques. The Bunnell and Tsuge core suture techniques produced the poorest mechanical performance. Conclusion From these experimental results, the new Marburg 1 core suture technique can be considered for flexor tendon repair in a clinical setting with the use of active motion protocols.
Eur J Trauma Emerg Surg (2011) 37:79–84 DOI 10.1007/s00068-010-0019-8 Received: 25 July 2009 / Accepted: 30 January 2010 / Published online: 20 April 2010