Intraobserver and interobserver repeatability of ocular  components measurement in cataract eyes using  a new optical low coherence reflectometer

Intraobserver and interobserver repeatability of ocular components measurement in cataract eyes using a new optical low coherence reflectometer

  • نوع فایل : کتاب
  • زبان : انگلیسی
  • مؤلف : Mirjana Bjeloš Ronèeviæ & Mladen Bušiæ & Ivan Èima & Biljana Kuzmanoviæ Elabjer & Damir Bosnar & Daliborka Miletiæ
  • چاپ و سال / کشور: 2010

Description

Background The purpose of the study was to assess intraobserver and interobserver repeatability of eight ocular components measurement in cataract eyes using the optical low-coherence reflectometer Lenstar LS 900®. Methods Five consecutive measurements of ocular components were taken by two examiners using the Lenstar. Components analyzed were: central corneal thickness, lens thickness, anterior chamber depth, axial length, retinal thickness, keratometry, white-to-white distance, and pupillometry. Within-subject standard deviation and the coefficient of variation were calculated for evaluation of intraobserver repeatability. Bland–Altman analysis was used for assessment of interobserver repeatability. Results Thirty-two eyes of 22 patients were included. For both observers, the smallest intraobserver coefficient of variation was obtained for axial length, while the largest was found for corneal steepest meridian position. Interobserver repeatability demonstrated less repeatable results for white-to-white distance and corneal steepest meridian position. Considering axial length and anterior chamber depth values, predicted refractive error was 0±0.05 D and 0.02±0.19 D respectively in 95% of observations. Conclusion The Lenstar LS 900® evidenced excellent repeatability and observers´ independent results of all components analyzed except white-to-white distance and corneal steepest meridian position measurements. To the best of our knowledge, this is the first study on interobserver repeatability of optical low-coherence reflectometry in cataract eyes.
Graefes Arch Clin Exp Ophthalmol (2011) 249:83–87 DOI 10.1007/s00417-010-1546-z Received: 30 May 2010 / Revised: 4 October 2010 / Accepted: 10 October 2010 / Published online: 28 October 2010
اگر شما نسبت به این اثر یا عنوان محق هستید، لطفا از طریق "بخش تماس با ما" با ما تماس بگیرید و برای اطلاعات بیشتر، صفحه قوانین و مقررات را مطالعه نمایید.

دیدگاه کاربران


لطفا در این قسمت فقط نظر شخصی در مورد این عنوان را وارد نمایید و در صورتیکه مشکلی با دانلود یا استفاده از این فایل دارید در صفحه کاربری تیکت ثبت کنید.

بارگزاری