Contact lenses vs spectacles in myopes: is there any  difference in accommodative and binocular function?

Contact lenses vs spectacles in myopes: is there any difference in accommodative and binocular function?

  • نوع فایل : کتاب
  • زبان : انگلیسی
  • مؤلف : Raimundo Jiménez & Loreto Martínez-Almeida & Carlos Salas & Carolina Ortíz
  • چاپ و سال / کشور: 2010

Description

Background Theoretically, the accommodative and vergence demands are different between single-vision contact lenses and spectacle lenses. The aim of the present study was to determine whether these differences exist when these two correction methods are used in clinical practice. For this, different visual parameters that characterize the accommodative (accommodation amplitude, accommodative facility, and accommodative response) and binocular function (near and distance horizontal and vertical dissociated phorias, near and vertical associated phorias, near and distance negative and positive fusional vergence, vergence facility, near point of convergence, negative and positive relative accommodation, stimulus AC:A ratio and stereoacuity) were evaluated in a student population when their myopia was corrected with either spectacles or soft contact lenses (SCL). Methods All parameters were measured on two separate occasions in 30 myopic habitual contact lens and spectacle wearers of mean age 19±2.4 years. Some parameters such as accommodation amplitude, accommodative response, and stimulus AC:A ratio were measured using two measurement methods which are commonly used in clinical practice. Three measurements were taken for each parameter and averaged. For the comparative statistical analysis, we used the Student’s t-test (p value<0.05). Results The following statistically significant differences were found with the use of SCL in comparison to spectacles: higher accommodative lags, higher negative relative accommodation, more esophoric near horizontal dissociated phoria, and lower negative fusional vergence in near vision. Conclusions The results found in this study show a definite trend towards poorer accommodative and vergence function with the use of contact lenses in comparison to glasses. This downward trend, though not statistically significant in accommodative function (lower PRA values and less lens amplitude of accommodation) might suggest that temporal insufficiency in the accommodation process could be occurring while contact lenses are used, thereby possibly creating a lag in accommodation to reduce associated overconvergence. This would be manifested in more esophoric values being found in the vergence function. The higher accommodative lags found in this study with SCL could indicate that prolonged use of SCL in near tasks may provoke a continuous hyperopic retinal defocus, a risk factor for the onset and progression of myopia, as indicated in numerous studies.
Graefes Arch Clin Exp Ophthalmol (2011) 249:925–935 DOI 10.1007/s00417-010-1570-z Received: 21 May 2010 / Revised: 18 October 2010 / Accepted: 3 November 2010 / Published online: 23 November 2010
اگر شما نسبت به این اثر یا عنوان محق هستید، لطفا از طریق "بخش تماس با ما" با ما تماس بگیرید و برای اطلاعات بیشتر، صفحه قوانین و مقررات را مطالعه نمایید.

دیدگاه کاربران


لطفا در این قسمت فقط نظر شخصی در مورد این عنوان را وارد نمایید و در صورتیکه مشکلی با دانلود یا استفاده از این فایل دارید در صفحه کاربری تیکت ثبت کنید.

بارگزاری