Angiographic findings following tack fixation of a wireless  epiretinal retina implant device in blind RP patients

Angiographic findings following tack fixation of a wireless epiretinal retina implant device in blind RP patients

  • نوع فایل : کتاب
  • زبان : انگلیسی
  • مؤلف : Gernot Roessler & Thomas Laube & Claudia Brockmann & Thomas Kirschkamp & Babac Mazinani & Johannes Menzel-Severing & Norbert Bornfeld & Peter Walte
  • چاپ و سال / کشور: 2011

Description

Background The fixation of polyimide stimulator foils as the basic substrate of epiretinal prostheses by using retinal tacks may cause retinal or choroidal alterations such as retinal proliferations or choroidal neovascularizations. During the prospective trial for the semichronical testing of a wireless intraocular retinal implant (EPIRET3) we investigated alterations in angiographic findings during implantation and after explantation of the device, to detect potential vascular pathologies at the fixation site or elsewhere. Methods As the final step of the implantation surgery in six blind patients, the stimulator was placed on the retinal surface using retinal tacks. For the detection of possible morphological or vascular alterations committed by the implant fluorescein angiography (FA) was performed 1 day before and 4 weeks after implantation surgery, as well as at the final visit 5 months after explantation. Results Following implantation surgery funduscopy and FA did not reveal any evidence of either vascular pathologies or choroidal neovascularisations (CNV), in addition, no cystoid macular edema (CME) occurred after 4 weeks. At the 6-month follow-up visit, we found a mild epiretinal gliosis formation in four patients. In one patient a retinal break occurred during explantation, requiring a temporary silicone-oil endotamponade. At the final visit, we observed a focal proliferative vitreoretinopathy (PVR) reaction without activity, while there was no evidence for a CNV formation in that area. Conclusions The FA findings confirm our previous results on the safety of the EPIRET3 system, which was tolerated in all patients but revealed a certain risk profile in regard to the stimulator fixation. While there was no evidence for newly occurred CME or CNV during the follow-up visits, nevertheless gliosis or even PVR reaction at the tack’s fixation site suggests the need to develop alternative fixation procedures of epiretinal stimulators.
Graefes Arch Clin Exp Ophthalmol DOI 10.1007/s00417-011-1653-5 Received: 15 July 2010 / Revised: 31 January 2011 / Accepted: 1 February 2011
اگر شما نسبت به این اثر یا عنوان محق هستید، لطفا از طریق "بخش تماس با ما" با ما تماس بگیرید و برای اطلاعات بیشتر، صفحه قوانین و مقررات را مطالعه نمایید.

دیدگاه کاربران


لطفا در این قسمت فقط نظر شخصی در مورد این عنوان را وارد نمایید و در صورتیکه مشکلی با دانلود یا استفاده از این فایل دارید در صفحه کاربری تیکت ثبت کنید.

بارگزاری