Novel algorithm for identifying T-wave current density alternans using synthesized 187-channel vector-projected body surface mapping

Novel algorithm for identifying T-wave current density alternans using synthesized 187-channel vector-projected body surface mapping

  • نوع فایل : کتاب
  • زبان : انگلیسی
  • مؤلف : Kenji Nakai Shin Takahashi Atsushi Suzuki Nobuhisa Hagiwara Keisuke Futagawa Morio Shoda Tsuyoshi Shiga Ken Takahashi Hitoshi Okabayas
  • چاپ و سال / کشور: 2010

Description

The noninvasive evaluation of ventricular T-wave alternans (TWA) in patients with lethal ventricular arrhythmias is an important issue. In this study, we propose a novel algorithm to identify T-wave current density alternans (TWCA) using synthesized 187-channel vector-projected body surface mapping (187-ch SAVP-ECG). We recorded 10 min of 187-ch SAVP-ECG using a Mason–Likar lead system in the supine position. A recovery time (RT) dispersion map was obtained by averaging the 187-ch SAVPECG. The TWCA value was determined from the relative changes in the averaged current density in the T-wave zone (Tpeak ± 50 ms) for two T-wave types. We registered 20 ECG recordings from normal controls and 11 ECG recordings from nine subjects with long QT syndrome (LQT). We divided LQT syndrome subjects into two groups: group 1 provided 9 ECG recordings without visually apparent TWAs, and group 2 provided 2 ECG recordings with visually apparent TWAs. The QTc interval values in the LQT groups were higher than those in the control (515 ± 60 ms in LQT G-1, 600 ± 27 ms in LQT G-2 vs. 415 ± 19 ms in control, P\0.001). The RTendc dispersion values among the LQT subjects were higher than those of the control subjects (48 ± 19 ms in LQT G-1, 65 ± 30 ms in LQT G-2 vs. 24 ± 10 ms in control, P\0.01). The mean TWCA value was significantly higher in the LQT G-2 group with visually apparent TWCAs (0.5 ± 0.2% in control, 2.1 ± 1.2% in LQT G-1, and 32.3 ± 6.9% in LQT G-2). Interestingly, the two-dimensional distribution of TWCA in LQT was inhomogeneous and correlated with the distribution of increased RT dispersion. We conclude that a novel algorithm using 187-ch SAVP-ECG might provide new insights into body surface TWCA.
Heart Vessels (2011) 26:160–167 DOI 10.1007/s00380-010-0042-z Received: 23 April 2009 / Accepted: 25 March 2010 / Published online: 30 October 2010
اگر شما نسبت به این اثر یا عنوان محق هستید، لطفا از طریق "بخش تماس با ما" با ما تماس بگیرید و برای اطلاعات بیشتر، صفحه قوانین و مقررات را مطالعه نمایید.

دیدگاه کاربران


لطفا در این قسمت فقط نظر شخصی در مورد این عنوان را وارد نمایید و در صورتیکه مشکلی با دانلود یا استفاده از این فایل دارید در صفحه کاربری تیکت ثبت کنید.

بارگزاری