The effect of an Er,Cr:YSGG laser on the micro-shear bond  strength of composite to the enamel and dentin  of human permanent teeth

The effect of an Er,Cr:YSGG laser on the micro-shear bond strength of composite to the enamel and dentin of human permanent teeth

  • نوع فایل : کتاب
  • زبان : انگلیسی
  • مؤلف : Zahra Jaberi Ansari & Reza Fekrazad & Saideh Feizi & Farnaz Younessian & Katayoun AM Kalhori & Norbert Gutknecht
  • چاپ و سال / کشور: 2011

Description

The bond strength of resin composite to Er,Cr: YSGG laser-irradiated enamel and dentin has been evaluated in only a few studies. Therefore, we measured and compared the micro-shear bond strength of composite restorations to enamel and dentin using two different cavity-preparation tools and conditioning methods. One hundred and seventy-five caries-free human third molars were sectioned longitudinally into two different thicknesses and randomly assigned to seven subgroups (n=25). Enamel groups included laser-cut without etching (LO), laser-cut and laser-etched (LL), laser-cut and acid-etched (LA), burcut and laser-etched (BL1), and bur-cut and acid-etched (BA1-comparison group). Dentinal groups included burcut and laser-etched (BL2) and bur-cut and acid-etched (BA2-comparison group). The specimens were bonded by Single Bond and Tygon tubes and were restored with Z100 composite. Failure patterns were evaluated using a stereomicroscope, and a shear bond test was performed at 0.5 mm/min. The mean shear bond strength values (MPa) for the LO, LL, LA, BL1 and BA1 enamel groups were 23.14, 23.77, 23.51, 19.30, and 28.99, respectively, whereas for the BL and BA dentinal groups, these values were 22.44 and 26.15, respectively. In enamel specimens, BA1 and LL groups presented the highest shear bond strength values, and the bur-cut and laser-etched (BL1) group showed the lowest values. In the laser-etched groups, bond strength values for bur-cut surfaces were significantly higher than those for laser-cut surfaces. Moreover, there was a significant difference between the BL2 and BA2 dentinal groups. The results of this study indicate that re-etching with acid phosphoric would be recommended if an Er,Cr:YSGG laser is used for tooth preparation or surface treatment.
Lasers Med Sci DOI 10.1007/s10103-011-0961-7 Received: 30 November 2010 / Accepted: 29 June 2011
اگر شما نسبت به این اثر یا عنوان محق هستید، لطفا از طریق "بخش تماس با ما" با ما تماس بگیرید و برای اطلاعات بیشتر، صفحه قوانین و مقررات را مطالعه نمایید.

دیدگاه کاربران


لطفا در این قسمت فقط نظر شخصی در مورد این عنوان را وارد نمایید و در صورتیکه مشکلی با دانلود یا استفاده از این فایل دارید در صفحه کاربری تیکت ثبت کنید.

بارگزاری